| Sign In | Join Free | My infospaceinc.com |
|
Place of Origin : CHINA
Supply Ability : 1000 PC/Month
Packaging Details : Seaworthy Packaging
Delivery Time : 5-8 weeks
MOQ : 1 PS
Brand Name : KW-TECH
Payment Terms : T/T
Advanced Liquid Cooling Server Rack for AI, HPC and High Density Computing
The High Density Liquid Cooling Server Rack is a liquid cooling infrastructure solution designed for AI data centers, high performance computing (HPC), GPU servers, and other high-density computing applications.
The rack integrates a structured coolant distribution system with vertical supply and return manifolds, multiple cooling connections, and flexible coolant hoses. It enables efficient distribution of cooling liquid to multiple server positions while simplifying pipe routing and system maintenance.
Compared with conventional air-cooled server racks, liquid cooling infrastructure provides a more effective approach to managing the high heat density generated by modern GPU and CPU servers. The rack can be integrated with CDU systems, cold plate cooling systems, and data center liquid cooling networks to build a complete thermal management solution.
High Density Liquid Cooling Design
Integrated Coolant Distribution
The rack incorporates vertical coolant distribution manifolds and multiple branch connections to provide organized coolant delivery to individual server positions.
Key functions include:
Optimized Pipeline Layout
The vertical manifold structure helps organize multiple coolant connections inside the rack, reducing unnecessary piping complexity and making installation and maintenance more convenient.
Flexible System Integration
The liquid cooling server rack can be integrated with:
Easy Maintenance
The modular distribution structure allows individual cooling connections to be inspected, replaced, or maintained without requiring major modifications to the overall cooling infrastructure.
The Liquid Cooling Server Rack is suitable for:
Efficient Cooling Distribution
The integrated manifold structure provides organized coolant distribution to multiple server positions, supporting efficient heat removal from high-density computing equipment.
Designed for AI and HPC
Modern AI servers and GPU clusters generate significantly higher heat loads than traditional IT equipment. A liquid cooling server rack provides the infrastructure required to support these high-density thermal management applications.
Space Efficient
Vertical coolant manifolds and organized hose routing make effective use of the available rack space while maintaining convenient access for installation and maintenance.
Flexible Configuration
The number of cooling branches, connection positions, manifold dimensions, pipe diameter, hose length, and interface specifications can be customized according to project requirements.
Easy Integration with CDU Systems
The rack can be connected to an upstream Coolant Distribution Unit (CDU) to create a complete liquid cooling loop between the facility cooling system and server-side cooling equipment.
| Parameter | Specification |
|---|---|
| Product Name | High Density Liquid Cooling Server Rack |
| Application | AI Data Center and HPC Liquid Cooling |
| Cooling Architecture | Liquid Cooling |
| Distribution Method | Vertical Supply and Return Manifolds |
| Cooling Connection | Customized |
| Number of Branches | Customized |
| Coolant | Water / Water Glycol Solution |
| Connection Type | Customized |
| Hose Type | Flexible Liquid Cooling Hose |
| Manifold Material | Stainless Steel / Customized |
| Rack Structure | Modular Frame |
| Installation | Floor Mounted |
| CDU Integration | Supported |
| Cold Plate Cooling | Supported |
| Direct-to-Chip Cooling | Supported |
| Dimensions | Customized |
| Communication | N/A or Integrated with Cooling Control System |
Supply Manifold
The supply manifold distributes conditioned coolant from the CDU or primary cooling system to individual server cooling circuits.
Return Manifold
The return manifold collects heated coolant from multiple server cooling loops and directs it back to the CDU or heat rejection system.
Flexible Cooling Hoses
Flexible hoses connect individual server cooling circuits to the manifold, allowing easier installation and accommodating equipment movement or maintenance requirements.
Rack Frame
The structural frame supports the manifolds, hoses, and associated cooling components while maintaining an organized and accessible installation layout.
Looking for a Liquid Cooling Server Rack for your AI data center, GPU cluster, or HPC liquid cooling project?
We provide customized liquid cooling rack solutions with different manifold configurations, cooling connections, hose assemblies, rack dimensions, and CDU integration options.
Contact us today for technical consultation, system configuration, and project quotation.
|
|
High Density Liquid Cooling Server Rack for AI Data Center Applications Images |